High and Low Temperature Test Machine
Model |
80L |
150L |
225L |
408L |
608L |
800L |
|
Internal Dimensions (W x H x D) (cm) |
40x50x40 |
50x60x50 |
60x75x50 |
80x85x60 |
80x95x80 |
100x100x80 |
|
External Dimensions (W x H x D) (cm) |
90x136x94 |
100x146x104 |
100x161x117 |
110x171x137 |
130x181x137 |
150x186x137 |
|
Performance Specifications |
Temperature Range |
-70℃~150℃ |
|||||
Temperature Fluctuation/Uniformity |
≤±0.5℃/+2℃-3℃ |
||||||
Heating Time |
-40℃~100℃约55min |
||||||
Cooling Time |
25℃~-70℃约80min |
||||||
Temperature and Humidity Control System |
Controller |
Imported LED digital display P, I, D+S, S, R microcomputer integrated controller |
|||||
Accuracy Range |
Setting accuracy: Temperature ±0.1℃, Display accuracy: Temperature ±0.1℃, Resolution: ±0.1℃ |
||||||
Temperature and Humidity Sensor |
Platinum resistance PT100Ω/MV |
||||||
Heating System |
Fully independent system, nickel-chromium alloy electric heating type heater |
||||||
Heating System |
Fully enclosed air-cooled single-stage compression refrigeration method / Fully enclosed air-cooled multi-stage compression refrigeration method |
||||||
Circulation System |
High-temperature, low-noise air-conditioning type motor with multi-blade centrifugal fan |
||||||
Materials Used |
External Casing Material |
High-quality carbon steel plate with phosphated electrostatic spray treatment / SUS304 stainless steel matte striped finish treatment |
|||||
Internal Casing Material |
SUS304 stainless steel high-quality mirror finish panel |
||||||
Insulation Material |
Polyurethane rigid foam, ultra-fine fiberglass insulation |
||||||
Door Frame Insulation |
Double-layer high and low-temperature aging-resistant silicone rubber door seals |
||||||
Standard Configuration |
Multi-layer heating touch screen with illuminated glass window (1 set), specimen rack (2 pieces), test lead hole (25, 50mm) (1 piece) |
||||||
|
Note: 1. The above data is measured under the condition of an ambient temperature (QT) of 25℃ and an unloaded test chamber. 2. Custom non-standard high and low temperature, low temperature test chambers can be made according to the specific requirements of the user. | |||||||